NOEMAC logo

NOEMAC

We operate at the intersection of medical imaging and maritime defense.

ASW Poseidon advances passive long-array sonar and command-and-control to improve underwater situational awareness for Anti-Submarine Warfare.

In parallel, our portable-ultrasound technology addresses a capability gap identified by the U.S. Army testing: the lack of field-ready devices for battlefield and emergency medicine.

Medical imaging and maritime defense.

Portable ultrasound fills a U.S. Army–identified field gap.

ASW Poseidon improves underwater awareness via passive long-arrays and C2.

Developed Technologies

About NOEMAC

Established July 2025 Subsidiary of ADICUS4D Ltd (Canada)

NOEMAC Ltd was established in July 2025 as a subsidiary of the Canadian corporation ADICUS4D Ltd. Our mission is to complete the development and commercialization of advanced geometrically multidimensional 3D beamformers and integrate them with AI decision-support systems.

The technologies were conceived and developed by Prof. Stergios Stergiopoulos (Senior & Chief Defence Scientist, DRDC Toronto, retired) and Prof. Konstantinos N. Plataniotis (University of Toronto).

Focus areas
  • Anti-Submarine Warfare (ASW) surveillance systems based on multidimensional beamforming.
  • Field-deployable 4D ultrasound with automated diagnostic capabilities for combat casualty and trauma care, and civilian emergency medicine.
Why it matters

Multidimensional beamformers fused with AI decision support deliver higher sensitivity, better localization, and faster operator decisions across maritime sensing and point-of-care medicine.

ASW Poseidon

ASW POSEIDON is NOEMAC’s antisubmarine warfare system, a state‑of‑the‑art passive surveillance sonar at TRL 9. It deploys either a sea‑bottom fixed long hydrophone array or a 200 m towed array at depths of about 100 m. For quiet submarines, the sea‑bottom fixed hydrophone arrays provide detection ranges of approximately 30 nautical miles (~55 km).

The signal‑processing algorithms combine advanced beamformers, spectral analysis, and a Passive Localization Assistant (PLA) aimed at addressing the rapid emergence of UUVs, their operational domains, and new communication and swarm behaviors. The goal is to introduce an AI‑based command‑and‑control (C2) solution that enhances underwater situational awareness for ASW operations, analogous in role to AWACS in the aerial domain.

TRL 9 Sea‑bottom fixed long array 200 m towed array @ ~100 m Quiet‑sub detection ~30 nm PLA / C2 (AWACS‑like)
Signal‑processing chain
  • Advanced beamformers (adaptive and synthetic aperture) for narrowband and broadband targets.
  • Spectral analysis for classification and track persistence.
  • Passive Localization Assistant (PLA) with C2 integration for UUVs, modern communications, and swarm behaviors.
Advantages versus competing products
  • Adaptive beamformers minimize strong noise from naval vessels to improve detection of quiet broadband targets.
  • Acoustic synthetic‑aperture beamformers improve array gain for narrowband signals by approximately 3.5 dB.
Performance characteristics from operational testing
  • Narrow‑band beamforming outputs for slowly moving underwater targets.
  • Spectral analysis for narrow‑band outputs used in classification.
  • Broad‑band beamforming outputs.
  • Signal trackers.
  • Passive Localization Assistant (PLA) for location assessment of detected NB/BB beams.
  • AI tool for automated target classification.

Operational evidence

Representative outputs from trials and evaluations.

The methodologies and findings have been validated and disseminated through peer‑reviewed scientific publications. See ASW selected references below.

The methodologies and findings have been validated and disseminated through peer-reviewed scientific publications. See ASW selected references below.

System Delivery & Consultations

Delivery timeline: within 16 months for a complete sea‑bottom mounted system that includes the hydrophone line array, supporting electronics, the full signal‑processing chain, and the command‑and‑control system.

Scope note: Deployment of the sea‑bottom mounted hydrophone array is not included. NOEMAC provides consultations for optimum underwater site selection with respect to sonar performance.

  • Numerical assessment of options for the sonar‑equation problem to achieve optimum performance.
  • Deployment procedures for sea‑bottom or towed configurations of line hydrophone arrays suited to sonar operations.
  • Training of sonar operators.
  • Maintenance support for hardware and software sub‑systems.

ASW Poseidon has been tested in operational environments, with assessment results published in Proceedings of the IEEE.

Selected References (ASW)

  1. Stergiopoulos, S. (1998). Implementation of Adaptive and Synthetic Aperture Beamformers in Sonar Systems. Proceedings of the IEEE, 86(2), 358–396.
  2. Stergiopoulos, S. (Ed.). (2009). Advanced Beamformers, in Handbook on Advanced Signal Processing for Sonar, Radar and Medical Imaging Systems (2nd ed.). CRC Press.
  3. Stergiopoulos, S. (1990). Optimum bearing resolution for a moving towed array and extension of its physical aperture. J. Acoust. Soc. Am., 87(5), 2128–2140.
  4. Stergiopoulos, S., & Sullivan, E. J. (1989). Extended towed array processing by overlapped correlator. J. Acoust. Soc. Am., 86(1), 158–171.
  5. Stergiopoulos, S., & Ashley, A. T. (1997). Split-beam processing as a broadband bearing estimator. J. Acoust. Soc. Am., 102(6), 3556–3563.
  6. Stergiopoulos, S. (1995). Noise normalization technique for beamformed towed array data. J. Acoust. Soc. Am., 97(4), 2334–2345.
  7. Stergiopoulos, S., & Urban, H. (1992). Forming a long synthetic aperture in the sea. IEEE J. Oceanic Eng., 17(1), 62–72.
  8. Stergiopoulos, S. (1991). Limitations on towed array gain in a non-isotropic ocean. J. Acoust. Soc. Am., 90(6), 3161–3172.

Portable Ultrasound

Portable 4D Ultrasound Automated Diagnostic System — a developed technology at TRL 6. It addresses a critical capability gap in battlefield medicine by delivering instant volumetric 3D/4D imaging with AI‑guided eFAST for detecting non‑compressible torso hemorrhage (NCTH) at the point of injury. A planar matrix‑array transducer with GPU‑accelerated beamforming (NVIDIA Jetson) enables ~20 volumes per second real‑time imaging with guided acquisition and automated interpretation.

TRL 6 (overall) 3D/4D volumetric AI‑guided eFAST NCTH detection Planar matrix array Jetson GPU ~20 vol/s Telemedicine GUI
Technology stack
  • Planar matrix‑array transducer capturing a full 3D volume per acquisition.
  • GPU‑accelerated beamforming on embedded NVIDIA Jetson for low‑latency volumetric imaging (~20 vol/s).
  • On‑device AI with guided prompts and automated interpretation for reliable eFAST workflows.
  • TeleConsult GUI with secure telemedicine communication to support remote consultation and training.
TRL snapshot by sub‑system
  • Matrix planar array probe — TRL 8 (two prototypes, tested at Fraunhofer IBMT).
  • Parallel computing architecture (8 FPGAs, 256 ADC / 256 DAC) — TRL 8.
  • 3D beamformer with volumetric reconstruction — TRL 7.
  • GUI with telemedicine (TeleConsult) — TRL 9 (integrated and validated in relevant environments).
  • Automated diagnostic tool (Morison’s pouch bleeding) — TRL 6 (phantom‑tested; clinical trials pending).
  • System integration (two real‑time 3D prototypes) — TRL 6.
Prototype & GUI imagery

Selected References (Portable Ultrasound)

  1. K. L. Amezcua, et al., "Design and Testing of Ultrasound Probe Adapters for a Robotic Imaging Platform," Scientific Reports, 14(1):5102, 2024. doi:10.1038/s41598-024-55480-0.
  2. Yuan Bi, et al., "Machine Learning on Robotic Ultrasound Imaging: Challenges and Perspectives," arXiv:2401.02376, 2024.
  3. Torres Hernandez, et al., "Evaluation of Deep Learning Model Architectures for Point-of-Care Ultrasound Diagnostics," Bioengineering, 11(4):392, 2024.
  4. D. C. Hile, et al., "Is Point‑of‑Care Ultrasound Accurate and Useful in the Hands of Military Medical Technicians?" Military Medicine, 177(8):983–987, 2012.
  5. J. D. Monti and M. D. Perreault, "Impact of a 4‑hour Introductory eFAST Training Intervention Among Ultrasound‑Naïve U.S. Military Medics," Military Medicine, 185(5‑6):e601‑e608, 2020.
  6. S. Stergiopoulos, K. Plataniotis, and M. Marsousi, "Optimal Probe Placement for FAST by Organ Segmentation in 3D Ultrasound Images," patent filed, DRDC File: 1416‑14/007CA, 2019.
  7. P. Weber, K. Plataniotis, S. Stergiopoulos, G. Sakas, et al., "Portable, 3D/4D Ultrasound Diagnostic Imaging System (PUDIS)," NATO HFM‑249 Symposium, Warsaw, April 2015.
  8. M. Marsousi, K. Plataniotis, and S. Stergiopoulos, "An Automated Approach for Kidney Segmentation in Three‑Dimensional Ultrasound Images," IEEE JBHI, 2016.
  9. M. Marsousi, K. Plataniotis, and S. Stergiopoulos, "Computer‑Assisted 3D Ultrasound Probe Placement for Emergency Healthcare Applications," IEEE TII, 2016.
  10. S. Stergiopoulos and A. Dhanantwari, "High Resolution 3D Ultrasound Imaging System Deploying a Multi‑Dimensional Array of Sensors," technical report/patent notes.
  11. S. Stergiopoulos and A. Dhanantwari, US Patent 6,719,696, 2004.
  12. S. Stergiopoulos and A. Dhanantwari, US Patent 6,482,160, 2002.
  13. S. Stergiopoulos, "3D Ultrasound System and Method," US Patent Application 61/777,321, 2018 (DND ref. 1416‑18003).
  14. S. Stergiopoulos, M. Marsousi, and K. Plataniotis, "Automated Diagnostics in 3D Ultrasound System and Method," US Patent Application 61/777,343, 2018 (DND ref. 1416‑18004).

Our Team

Prof. Stergios Stergiopoulos, Ph.D.

Chief Innovation – Technology Officer, Director

View profile →

Prof. Konstantinos (Kostas) N. Plataniotis, Ph.D., P.Eng., FEIC, FCAE, FIEEE

Chief Executive Officer

View profile →

Stamatis Tzelepis, Ph.D.

Chief Software Engineer

View profile →

Georgios Karagiannis, Ph.D.

Chief Hardware Architect

View profile →

Georgios Sakkas, Ph.D.

Chief Software Imaging

View profile →

Christos Korgialas, Ph.D.(c)

Senior Software Engineer

View profile →

Dr. Ilda Hobdari, M.D., CCFP

Medical Practice Adviser

View profile →

Meet the full team →

Contact

Email: info@noemac.com

Phone: +30 697 198 5455

Address: Eleftherou Anthropou 21, Glyfada, Athens 16562